Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
test-and-measurement:guides:waveforms-logic-analyzer [2021/05/14 23:07] – ↷ Links adapted because of a move operation Arthur Browntest-and-measurement:guides:waveforms-logic-analyzer [2024/02/29 14:08] (current) – [Using the Logic Analyzer] replaced image Fausto Soares
Line 3: Line 3:
 ~~TechArticle~~ ~~TechArticle~~
  
-{{reference:test-and-measurement:analog-discovery-studio:hardware-reference-manual:logic-analyzer.png?nolink&800}}+{{test-and-measurement/analog-discovery-pro-2230/logic-screenshot.png?nolink|}}
  
 ===== Introduction ===== ===== Introduction =====
Line 10: Line 10:
 ===== Prerequisites ===== ===== Prerequisites =====
   * A Digilent Test & Measurement Device with Digital Inputs:   * A Digilent Test & Measurement Device with Digital Inputs:
 +    * [[test-and-measurement:analog-discovery-3:start|Analog Discovery 3]]
 +    * [[test-and-measurement:analog-discovery-pro-5250:start|Analog Discovery Pro (ADP5250)]]
     * [[test-and-measurement:analog-discovery-pro-3x50:start|Analog Discovery Pro (ADP3450/ADP3250)]]     * [[test-and-measurement:analog-discovery-pro-3x50:start|Analog Discovery Pro (ADP3450/ADP3250)]]
 +    * [[test-and-measurement:analog-discovery-pro-2230:start|Analog Discovery Pro (ADP2230)]]
     * [[test-and-measurement:analog-discovery-studio:start|Analog Discovery Studio]]     * [[test-and-measurement:analog-discovery-studio:start|Analog Discovery Studio]]
     * [[test-and-measurement:digital-discovery:start|Digital Discovery]]     * [[test-and-measurement:digital-discovery:start|Digital Discovery]]
Line 69: Line 72:
 </WRAP> </WRAP> </WRAP> </WRAP>
 ---- ----
-A [[https://store.digilentinc.com/digital-discovery-high-speed-adapter-and-logic-probes/|High Speed Adapter]] is available for the Digital Discovery which can be used to take advantage of the highest sampling frequencies the device offers.+A [[https://digilent.com/shop/digital-discovery-high-speed-adapter-and-logic-probes/|High Speed Adapter]] is available for the Digital Discovery which can be used to take advantage of the highest sampling frequencies the device offers.
 --> Click here if using the Digital Discovery High Speed Adapter # --> Click here if using the Digital Discovery High Speed Adapter #
 <WRAP group> <WRAP column half> <WRAP group> <WRAP column half>
-This adapter should be connected to the Digital Discovery's "HIGH SPEED INPUTS" pin group with the Ground symbols (downward facing arrows) pointing to the bottom of the device. While the adapter can be connected "upside down", doing so will result in the pin names shown in the [[https://reference.digilentinc.com/reference/instrumentation/digital-discovery/reference-manual#accessories|Digital Discovery Reference Manual]] not matching the actual pin names. Note that these pins cannot be used for digital output.+This adapter should be connected to the Digital Discovery's "HIGH SPEED INPUTS" pin group with the Ground symbols (downward facing arrows) pointing to the bottom of the device. While the adapter can be connected "upside down", doing so will result in the pin names shown in the [[test-and-measurement/digital-discovery/reference-manual#accessories|Digital Discovery Reference Manual]] not matching the actual pin names. Note that these pins cannot be used for digital output.
  
 If desired, one of these input pins can be used in this guide, along with any of the Digital Discovery's output-capable pins. Connect one of the provided black/red differential probes to the High Speed Adapter. Make sure that the black cable is connected to the side with the ground arrow. The black cable should be connected to the ground of the device under test (in this case, the Digital Discovery's ground). The red cable (the positive side of the p/n differential pair) should be connected to the chosen digital output. If desired, one of these input pins can be used in this guide, along with any of the Digital Discovery's output-capable pins. Connect one of the provided black/red differential probes to the High Speed Adapter. Make sure that the black cable is connected to the side with the ground arrow. The black cable should be connected to the ground of the device under test (in this case, the Digital Discovery's ground). The red cable (the positive side of the p/n differential pair) should be connected to the chosen digital output.
Line 358: Line 361:
 For more information on WaveForms visit the [[software:waveforms:waveforms-3:reference-manual|WaveForms Reference Manual]].  For more information on WaveForms visit the [[software:waveforms:waveforms-3:reference-manual|WaveForms Reference Manual]]. 
  
-For technical support, please visit the [[https://forum.digilentinc.com/forum/8-scopes-instruments/|Scopes and Instruments]] section of the Digilent Forums.+For technical support, please visit the [[https://forum.digilent.com/forum/8-test-and-measurement/|Test and Measurement]] section of the Digilent Forums.