Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
test-and-measurement:analog-discovery-pro-5250:start [2022/08/07 11:58] – [Featured Projects] Keith M Kolmostest-and-measurement:analog-discovery-pro-5250:start [2024/02/28 14:41] (current) – [Tutorials] James Colvin
Line 1: Line 1:
 +~~NOTOC~~ 
 +    
 +====== Analog Discovery Pro (ADP5250) ======
 +{{Digilent Infobox
 +| Store Page = https://digilent.com/shop/analog-discovery-pro-adp5250-all-in-one-1gs-s-100mhz-mixed-signal-oscilloscope-function-generator-power-supply-and-dmm/
 +| Getting Started = getting-started-guide
 +| Manual = [[reference-manual]]
 +| Support = https://forum.digilent.com/forum/8-scopes-instruments/
 +| Title = Analog Discovery Pro (ADP5250)
 +| Subtitle = Portable High Resolution Mixed Signal Oscilloscopes
  
 +| Header = Software
 +| WaveForms = [[software:waveforms:waveforms-3:start|Resource Center]]
 +| WaveForms SDK = [[software:waveforms:waveforms-sdk:start|Resource Center]]
 +| Bullet = The ADP5250 is Windows® only
 +
 +| Header = Mixed Signal Oscilloscope - Analog Inputs
 +| Channels = 2 single ended, non-isolated
 +| Resolution = 8 bits
 +| Sample Rate = 1 GS/s single channel, 500 MS/s per channel in dual channel mode
 +| Input Range = 40 V peak to peak, maximum
 +| Bandwidth (-3dB) = 100 MHz
 +| Input Impedance = 1 MΩ ││ 20 pF
 +| Accuracy = ±2% of input / ±1% full scale
 +| Buffer Size = 1 MS per channel, maximum
 +
 +| Header = Mixed Signal Oscilloscope - Digital Inputs
 +| Channels = 32
 +| Sample Rate = 1 GS/s
 +| Record Length = 1 MS typical
 +| Input Voltage = 0 V to 5 V
 +| Input Threshold = 0 V to 2 V
 +
 +| Header = Arbitrary Waveform Generator (Wavegen)
 +| Channels = 1
 +| Resolution = 14 bits
 +| Sample Rate = 125 MS/s 
 +| Output Impedance = 50 Ω
 +| Switchable Filter = 36 MHz lowpass, 7-pole, elliptical
 +| Output Range =  ±12 V, maximum
 +| DC Offset = ±12 V, maximum
 +
 +| Header = Data Logger
 +| Channels = 2 (Shared with Oscilloscope)
 +| Supported Measurements = DC, True RMS, AC RMS, Custom
 +
 +| Header = Programmable Power Supply
 +| Outputs = 0 to +6 V / 0 to 1 A \\ 0 to +25 V / 0 to 500 mA (isolated) \\ 0 to -25 V / 0 to 500 mA (isolated)
 +
 +| Header = Digital Multimeter
 +| Measurements = DC Voltage, AC Voltage, AC Current, Resistance, Diode, Continuity
 +| Digits = 5½
 +| Sample Rate = 5 S/s
 +
 +| Header = Digital I/O
 +| Channels = 8
 +| Logic Level = 5 V compatible TTL input / 3.3 V LVTTL output
 +
 +| Header = Logic Analyzer
 +| Bullet = Shares digital inputs with Mixed Signal Oscilloscope
 +
 +| Header = Spectrum Analyzer
 +| Inputs = Shared with Oscilloscope
 +| Frequency Range = DC to max bandwidth of scope
 +| Display Modes = magnitude, average, peak hold, min hold, count
 +
 +| Header = Network Analyzer
 +| Inputs / Outputs = Shared with Oscilloscope and Waveform Generator 
 +| Frequency Sweep Range = 1 mHz to 10 MHz
 +
 +| Header = Product Compliance
 +| HTC = 8471809000
 +| ECCN = 3A992.a
 +
 +}}
 +
 +{{page>reference-manual}} \\ \\
 +
 +===== Getting Started =====
 +  * [[getting-started-guide|Getting Started Guide]]
 +
 +
 +----
 +===== Documentation =====
 +  * [[reference-manual|Reference Manual]]
 +  * [[specifications|Specifications]]
 +/* * [[features|Feature List]] */
 +/* * [[FAQ]] */
 +
 +----
 +===== Tutorials =====
 +=== WaveForms Instruments ===
 +  * [[test-and-measurement:guides:waveforms-oscilloscope]]
 +  * [[test-and-measurement:guides:waveforms-waveform-generator]]
 +  * [[test-and-measurement:guides:waveforms-readback-supplies]]
 +  * [[test-and-measurement:guides:waveforms-dmm]]
 +  * [[test-and-measurement:guides:waveforms-data-logger]]
 +  * [[test-and-measurement:guides:waveforms-logic-analyzer]]
 +  * [[test-and-measurement:guides:waveforms-static-io]]
 +  * [[test-and-measurement:guides:waveforms-spectrum-analyzer]]
 +  * [[test-and-measurement:guides:waveforms-network-analyzer]]
 +  * [[test-and-measurement:guides:waveforms-impedance-analyzer]]
 +  * [[test-and-measurement:guides:waveforms-script-editor]]
 +
 +
 +=== Other Tutorials ===
 +  * [[test-and-measurement:guides:waveforms-calibration]]
 +  * [[test-and-measurement:guides:probe-compensation]]
 +  * [[test-and-measurement:guides:waveforms-sharing]]
 +  * [[test-and-measurement:guides:waveforms-cross-triggers]]
 +  * [[test-and-measurement:guides:waveforms-external-triggers]]
 +  * [[test-and-measurement:guides:waveforms-sdk-getting-started]]
 +  * [[test-and-measurement:guides:getting-started-with-labview]]
 +
 +----
 +===== Featured Projects =====
 +  * [[transistor-tester]]
 +  * [[power-measurement-demo]]
 +  * [[rf-demo]]
 +  * [[fm-radio]]
 +
 +----
 +/*
 +===== Highlighted Community Projects =====
 +----
 +*/
 +/*
 +===== Hackster Projects =====
 +
 +A complete list of Hackster projects featuring the Analog Discovery Studio can be found on [[https://projects.digilentinc.com/projects?part_id=110996&sort=trending|projects.digilentinc.com]]
 +
 +----
 +*/
 +
 +===== Additional Resources =====
 +  * [[certifications]]
 +  * {{https://files.digilent.com/resources/test-and-measurement/analog-discovery-pro-5250/adp5250-statement-of-volatility.pdf|Statement of Volatility}}
 +
 +/*https://www.ni.com/en-us/support/documentation/dimensional-drawings/model.vb-8012.html 2D and 3D models of virtual bench
 +https://www.ni.com/pdf/manuals/371528e.pdf calibration procedure
 +https://www.ni.com/pdf/manuals/375043d.pdf only documentation mentioned the scope compensation tabs on the front panel*
 +
 +----
 +/*
 +===== All Pages, Uncategorized (Temporary) =====
 +<nspages -simplelist -subns -title -hideNoPages>
 +*/
 +{{tag>resource-center}}