Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
test-and-measurement:analog-discovery-pro-5250:start [2022/02/21 21:07] – change listed specs to better reflect what is on the store features Arthur Browntest-and-measurement:analog-discovery-pro-5250:start [2024/02/28 22:41] (current) – [Tutorials] James Colvin
Line 6: Line 6:
 | Getting Started = getting-started-guide | Getting Started = getting-started-guide
 | Manual = [[reference-manual]] | Manual = [[reference-manual]]
-| Support = https://forum.digilentinc.com/forum/8-scopes-instruments/+| Support = https://forum.digilent.com/forum/8-scopes-instruments/
 | Title = Analog Discovery Pro (ADP5250) | Title = Analog Discovery Pro (ADP5250)
 | Subtitle = Portable High Resolution Mixed Signal Oscilloscopes | Subtitle = Portable High Resolution Mixed Signal Oscilloscopes
Line 40: Line 40:
 | Output Range =  ±12 V, maximum | Output Range =  ±12 V, maximum
 | DC Offset = ±12 V, maximum | DC Offset = ±12 V, maximum
 +
 +| Header = Data Logger
 +| Channels = 2 (Shared with Oscilloscope)
 +| Supported Measurements = DC, True RMS, AC RMS, Custom
  
 | Header = Programmable Power Supply | Header = Programmable Power Supply
Line 46: Line 50:
 | Header = Digital Multimeter | Header = Digital Multimeter
 | Measurements = DC Voltage, AC Voltage, AC Current, Resistance, Diode, Continuity | Measurements = DC Voltage, AC Voltage, AC Current, Resistance, Diode, Continuity
-| Digits = 5 1/2+| Digits = 
 | Sample Rate = 5 S/s | Sample Rate = 5 S/s
  
 | Header = Digital I/O | Header = Digital I/O
-| Bullet = Used in the Static I/O instrument 
 | Channels = 8 | Channels = 8
-| Logic level = 5 V compatible TTL input / 3.3 V LVTTL output+| Logic Level = 5 V compatible TTL input / 3.3 V LVTTL output
  
 | Header = Logic Analyzer | Header = Logic Analyzer
Line 65: Line 68:
 | Inputs / Outputs = Shared with Oscilloscope and Waveform Generator  | Inputs / Outputs = Shared with Oscilloscope and Waveform Generator 
 | Frequency Sweep Range = 1 mHz to 10 MHz | Frequency Sweep Range = 1 mHz to 10 MHz
-| Samples = up to 10k samples per decade 
  
 | Header = Product Compliance | Header = Product Compliance
Line 91: Line 93:
   * [[test-and-measurement:guides:waveforms-oscilloscope]]   * [[test-and-measurement:guides:waveforms-oscilloscope]]
   * [[test-and-measurement:guides:waveforms-waveform-generator]]   * [[test-and-measurement:guides:waveforms-waveform-generator]]
-  * [[test-and-measurement:guides:waveforms-supplies]]+  * [[test-and-measurement:guides:waveforms-readback-supplies]]
   * [[test-and-measurement:guides:waveforms-dmm]]   * [[test-and-measurement:guides:waveforms-dmm]]
 +  * [[test-and-measurement:guides:waveforms-data-logger]]
   * [[test-and-measurement:guides:waveforms-logic-analyzer]]   * [[test-and-measurement:guides:waveforms-logic-analyzer]]
   * [[test-and-measurement:guides:waveforms-static-io]]   * [[test-and-measurement:guides:waveforms-static-io]]
Line 103: Line 106:
 === Other Tutorials === === Other Tutorials ===
   * [[test-and-measurement:guides:waveforms-calibration]]   * [[test-and-measurement:guides:waveforms-calibration]]
 +  * [[test-and-measurement:guides:probe-compensation]]
   * [[test-and-measurement:guides:waveforms-sharing]]   * [[test-and-measurement:guides:waveforms-sharing]]
   * [[test-and-measurement:guides:waveforms-cross-triggers]]   * [[test-and-measurement:guides:waveforms-cross-triggers]]
   * [[test-and-measurement:guides:waveforms-external-triggers]]   * [[test-and-measurement:guides:waveforms-external-triggers]]
-  * [[test-and-measurement:guides:waveforms-using-waveforms-sdk]]+  * [[test-and-measurement:guides:waveforms-sdk-getting-started]] 
 +  * [[test-and-measurement:guides:getting-started-with-labview]]
  
 ---- ----
 ===== Featured Projects ===== ===== Featured Projects =====
 +  * [[transistor-tester]]
   * [[power-measurement-demo]]   * [[power-measurement-demo]]
 +  * [[rf-demo]]
 +  * [[fm-radio]]
  
 ---- ----
Line 126: Line 134:
  
 ===== Additional Resources ===== ===== Additional Resources =====
-  * {{reference:test-and-measurement:analog-discovery-pro-5250:adp5250_statement_of_volatility.pdf|Statement of Volatility}}+  * [[certifications]] 
 +  * {{https://files.digilent.com/resources/test-and-measurement/analog-discovery-pro-5250/adp5250-statement-of-volatility.pdf|Statement of Volatility}} 
 + 
 +/*https://www.ni.com/en-us/support/documentation/dimensional-drawings/model.vb-8012.html 2D and 3D models of virtual bench 
 +https://www.ni.com/pdf/manuals/371528e.pdf calibration procedure 
 +https://www.ni.com/pdf/manuals/375043d.pdf only documentation mentioned the scope compensation tabs on the front panel*
  
 ---- ----