Differences
This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
test-and-measurement:analog-discovery-pro-5250:specifications [2022/02/19 00:41] – [Digital I/O] Arthur Brown | test-and-measurement:analog-discovery-pro-5250:specifications [2023/12/18 19:55] (current) – James Colvin | ||
---|---|---|---|
Line 1: | Line 1: | ||
====== Analog Discovery Pro (ADP5250) Specifications ====== | ====== Analog Discovery Pro (ADP5250) Specifications ====== | ||
+ | /* | ||
+ | Additional material for ADP5470 and ADP5490. | ||
+ | https:// | ||
+ | https:// | ||
+ | |||
+ | https:// | ||
+ | https:// | ||
+ | |||
+ | PDFs of NI publicly published Specifications, | ||
+ | |||
+ | */ | ||
+ | |||
+ | |||
~~TechArticle~~ | ~~TechArticle~~ | ||
These specifications are valid following 30 minutes of warmup and are typical at 25 °C unless otherwise noted. | These specifications are valid following 30 minutes of warmup and are typical at 25 °C unless otherwise noted. | ||
Line 6: | Line 19: | ||
==== Analog Input Channels ==== | ==== Analog Input Channels ==== | ||
- | Supports the Oscilloscope, | + | Supports the Oscilloscope, Data Logger, Spectrum Analyzer, Network Analyzer, Impedance Analyzer, and Script Editor instruments. |
=== Vertical System === | === Vertical System === | ||
Line 25: | Line 38: | ||
|<100% 25%>| | |<100% 25%>| | ||
- | ^ Maximum Sampling Rate | 1 GS/s single channel, 500 MS/s per channel, dual channel || | + | ^ Maximum Sampling Rate | 1 GS/s single channel |
^ Maximum Record Length | 1 MS per channel || | ^ Maximum Record Length | 1 MS per channel || | ||
---- | ---- | ||
==== Digital Channels / Logic Analyzer ==== | ==== Digital Channels / Logic Analyzer ==== | ||
+ | Supports the Logic Analyzer and Script Editor instruments. | ||
{{ : | {{ : | ||
Line 35: | Line 49: | ||
=== Vertical System === | === Vertical System === | ||
|<100% 40%>| | |<100% 40%>| | ||
- | ^ Number of Channels | 34 || | + | ^ Number of Channels | 34 [(At time of writing, WaveForms software does not support use of the CLK0/CLK1 lines. All 32 DIO pins are fully supported.)] |
^ Maximum Input Frequency | 100 MHz || | ^ Maximum Input Frequency | 100 MHz || | ||
^ Input Voltage | 0 V to 5 V || | ^ Input Voltage | 0 V to 5 V || | ||
Line 45: | Line 59: | ||
**Note:** Mixed signal oscilloscope digital channels are designed to withstand accidental overvoltage from signals on the ADP5250. They are not recommended for use with signals likely to exceed 0 V to 5 V in normal operation. | **Note:** Mixed signal oscilloscope digital channels are designed to withstand accidental overvoltage from signals on the ADP5250. They are not recommended for use with signals likely to exceed 0 V to 5 V in normal operation. | ||
+ | |||
+ | ~~REFNOTES~~ | ||
=== Horizontal System === | === Horizontal System === | ||
Line 73: | Line 89: | ||
|<100% 25% 25%>| | |<100% 25% 25%>| | ||
- | ^ Waveforms | + | ^ Waveforms |
- | ^ Update Rate || 125 MS/s | + | ^ Update Rate |
- | ^ Resolution | + | ^ Resolution |
- | ^ Number of Channels | + | ^ Number of Channels |
- | ^ Output Impedance | + | ^ Output Impedance |
- | ^ Sine ^ Maximum Frequency | + | ^ Switchable Filter |
- | ^ ::: | + | ^ Sine |
- | ^ ::: | + | | ::: ^ Total Harmonic Distortion (1 MHz) |
- | ^ ::: | + | | ::: ^ Total Harmonic Distortion (10 MHz) | -50 dBc |
- | ^ ::: | + | | ::: ^ Spurious Free Dynamic Range (SFDR) |
- | ^ Square | + | | ::: ^ Phase Noise (1 MHz) |
- | ^ ::: | + | ^ Square |
- | ^ ::: | + | | ::: ^ Rise / Fall Time | <20 ns (10% to 90%) |
- | ^ ::: | + | | ::: ^ Overshoot |
- | ^ Ramp / Triangle Maximum Frequency | + | | ::: ^ Jitter |
- | ^ Accuracy (with >10 kΩ load) ^ Amplitude (1 kHz sine) | + | ^ Ramp / Triangle Maximum Frequency |
- | ^ ::: ^ DC | + | ^ Accuracy (with >10 kΩ load) ^ Amplitude (1 kHz sine) | ±(1% of output value ±5 mV) |
- | ^ Output Range | + | | ::: ^ DC | ±(1% of output value ±7.5 mV) |
- | ^ ::: ^ Hi-Z (>10 kΩ) | ±12 V | | + | ^ Output Range |
- | ^ DC Offset | + | | ::: ^ Hi-Z (>10 kΩ) |
- | ^ ::: ^ Hi-Z (>10 kΩ) | ±12 V | | + | ^ DC Offset |
- | ^ Frequency | + | | ::: ^ Hi-Z (>10 kΩ) |
- | ^ ::: ^ Resolution | + | ^ Frequency |
- | ^ Arbitrary Waveforms | + | | ::: ^ Resolution |
- | ^ ::: ^ Sample Rate | 125 MS/s | + | ^ Arbitrary Waveforms |
- | ^ Protection | + | | ::: ^ Sample Rate |
+ | ^ Protection | ||
**Note:** The combination of signal amplitude and DC offset cannot exceed the output range specifications. The impedances listed are the loads applied by the user to the Waveform Generator output. | **Note:** The combination of signal amplitude and DC offset cannot exceed the output range specifications. The impedances listed are the loads applied by the user to the Waveform Generator output. | ||
Line 318: | Line 335: | ||
---- | ---- | ||
===== Power Requirements ===== | ===== Power Requirements ===== | ||
- | |<100% 25%> | + | |<100% 25%>| |
- | + | ^ Voltage Input Range | 100 V AC to 240 V AC, ±10%, 50/60 Hz || | |
- | ^ Voltage Input Range | 100 V AC to 240 V AC, 50/60 Hz || | + | |
^ Power Consumption | 100 W maximum || | ^ Power Consumption | 100 W maximum || | ||
^ Power Input Connector | IEC C13 power connector || | ^ Power Input Connector | IEC C13 power connector || | ||
Line 343: | Line 359: | ||
==== DMM Isolation Voltages (Ground to Earth) ==== | ==== DMM Isolation Voltages (Ground to Earth) ==== | ||
+ | |||
+ | <columns 100% 5% 95%> | ||
+ | {{: | ||
+ | < | ||
+ | **Hazardous Voltage:** This icon denotes a warning advising you to take precautions to avoid electrical shock. | ||
+ | </ | ||
+ | |||
+ | === Channel-to-earth Ground === | ||
|<100% 25%>| | |<100% 25%>| | ||
^ Continuous | 300 V, Measurement Category II || | ^ Continuous | 300 V, Measurement Category II || | ||
Line 350: | Line 374: | ||
Measurement Category II is for measurements performed on circuits directly connected to the electrical distribution system. This category refers to local-level electrical distribution, | Measurement Category II is for measurements performed on circuits directly connected to the electrical distribution system. This category refers to local-level electrical distribution, | ||
+ | |||
+ | <columns 100% 5% 95%> | ||
+ | {{: | ||
+ | < | ||
+ | **Caution: | ||
+ | </ | ||
==== DC Power Supply Isolation Voltages ==== | ==== DC Power Supply Isolation Voltages ==== | ||
|<100% 25%>| | |<100% 25%>| | ||
- | ^ +25V and -25V to earth ground, continuous | 60VDC, Measurement Category 1 ||| | + | ^ +25V and -25V to earth ground, continuous | 60 VDC, Measurement Category 1 ||| |
+ | |||
+ | **Note:** // | ||
---- | ---- | ||
Line 377: | Line 409: | ||
---- | ---- | ||
- | + | {{page> | |
- | ==== Safety ==== | + | |
- | This product is designed to meet the requirements of the following electrical equipment safety standards for measurement, | + | |
- | * IEC 61010-1, EN 61010-1 | + | |
- | * UL 61010-1, CSA 61010-1 | + | |
---- | ---- | ||
- | + | All specifications provided courtesy | |
- | ==== Electromagnetic Compatibility ==== | + | |
- | + | ||
- | This product meets the requirements | + | |
- | * EN 61326-1 (IEC 61326-1): Class A emissions; Basic immunity | + | |
- | * EN 55011 (CISPR 11): Group 1, Class A emissions | + | |
- | * EN 55022 (CISPR 22): Class A emissions | + | |
- | * EN 55024 (CISPR 24): Immunity | + | |
- | * AS/NZS CISPR 11: Group 1, Class A emissions | + | |
- | * AS/NZS CISPR 22: Class A emissions | + | |
- | * FCC 47 CFR Part 15B: Class A emissions | + | |
- | * ICES-001: Class A emissions | + | |
- | + | ||
- | **Note:** In the United States (per FCC 47 CFR), Class A equipment is intended for use in commercial, light-industrial, | + | |
- | + | ||
- | **Note:** Group 1 equipment (per CISPR 11) is any industrial, scientific, or medical equipment that does not intentionally generate radio frequency energy for the treatment of material or inspection/analysis purposes. | + | |
- | + | ||
- | **Note:** For EMC declarations and certifications, | + | |
- | + | ||
- | + | ||
- | ---- | + | |
- | + | ||
- | ====CE Compliance==== | + | |
- | This product meets the essential requirements of applicable European Directives, as follows: | + | |
- | * 2014/35/EU; Low-Voltage Directive (safety) | + | |
- | * 2014/30/EU; Electromagnetic Compatibility Directive (EMC) | + |