 ====== OpenLogger - Calibration ====== ====== OpenLogger - Calibration ======
 +
 +===== First-Time Calibration =====
  
 Before being used for the first time, a new OpenLogger must first be calibrated. This process determines constants used to accurately calculate analog voltages for data points being logged, and stores these constants in non-volatile memory. Before being used for the first time, a new OpenLogger must first be calibrated. This process determines constants used to accurately calculate analog voltages for data points being logged, and stores these constants in non-volatile memory.
 +
 +**Note:** //After first-time calibration, described in this guide, a device can be recalibrated, if desired, through its Configuration Menu, found through the Device Manager in WaveForms Live.//
  
 ---- ----
Line 10: Line 15:
 When the device is connected to WaveForms Live for the first time, a prompt to calibrate the OpenLogger will appear. Click **OK**. When the device is connected to WaveForms Live for the first time, a prompt to calibrate the OpenLogger will appear. Click **OK**.
  
-**Note:** //After first-time calibration, a device can be recalibrated, if desired, by clicking the CALIBRATE button in its configuration screen.// 
 </WRAP> </WRAP>
 <WRAP column half> <WRAP column half>
-{{ :reference:instrumentation:openlogger:Uncalibrated_device_prompt.png?500 |Calibrate your device}}+{{ reference:test-and-measurement:openlogger:uncalibrated_device_prompt.png?500 |Calibrate your device}}
 </WRAP> </WRAP>
 </WRAP> </WRAP>
Line 20: Line 24:
 <WRAP column half> <WRAP column half>
 === 2. === === 2. ===
-Connect the provided 2x18 flywires to the OpenLogger with the nub side facing towards the center of the OpenLogger. +Connect the provided 2x18 flywires to the OpenLogger with the **__nub side facing towards the center__** of the OpenLogger. 
 +----
 === 3. === === 3. ===
-Connect the red wire on pin 6 (DC OUTPUT 1) to the solid orange wire on pin 35 (Analog Input 1). Take a look at the [[:reference:instrumentation:openlogger:reference-manual#openlogger_pinout|OpenLogger Pinout]] in the Reference Manual for details on which wire corresponds to which OpenLogger pin.+Connect the red wire on pin 6 (DC OUTPUT 1) to the solid orange wire on pin 35 (Analog Input 1). Take a look at the [[test-and-measurement:openlogger:reference-manual#openlogger_pinout|OpenLogger Pinout]] in the Reference Manual for details on which wire corresponds to which OpenLogger pin.
 </WRAP> </WRAP>
 <WRAP column half> <WRAP column half>
-{{ https://reference.digilentinc.com/_media/learn/instrumentation/tutorials/openlogger/calib-1.png?500 |Connect the red and orange wires}}+{{ /learn/instrumentation/tutorials/openlogger/calib-1.png?500 |Connect the red and orange wires}} 
 </WRAP> </WRAP>
 </WRAP> </WRAP>
Line 36: Line 41:
 </WRAP> </WRAP>
 <WRAP column half> <WRAP column half>
-{{ :reference:instrumentation:openlogger:Calibration_step_1.png?500 |Begin the calibration process}}+{{ reference:test-and-measurement:openlogger:calibration_step_1.png?500 |Begin the calibration process}}
 </WRAP> </WRAP>
 </WRAP> </WRAP>
Line 46: Line 51:
 </WRAP> </WRAP>
 <WRAP column half> <WRAP column half>
-{{ :reference:instrumentation:openlogger:starting_calibration_process.png?500 |Calibration progress bar}}+{{ reference:test-and-measurement:openlogger:starting_calibration_process.png?500 |Calibration progress bar}}
 </WRAP> </WRAP>
 </WRAP> </WRAP>
Line 59: Line 64:
 </WRAP> </WRAP>
 <WRAP column half> <WRAP column half>
-{{ https://reference.digilentinc.com/_media/learn/instrumentation/tutorials/openlogger/calib-2.png?500 |Start step 2}}+{{ /learn/instrumentation/tutorials/openlogger/calib-2.png?500 |Start step 2}}
 </WRAP> </WRAP>
 </WRAP> </WRAP>
Line 66: Line 71:
 <WRAP column half> <WRAP column half>
 === 8. === === 8. ===
-A final calibration complete screen will appear. Click the **DONE** button. +A final calibration complete screen will appear. Click the **DONE** button - see the image to the right
-</WRAP> +----
-<WRAP column half> +
-{{ :reference:instrumentation:openlogger:calibration_complete.png?500 |Calibration complete}} +
-</WRAP> +
-</WRAP> +
- +
-<WRAP group> +
-<WRAP column half>+
 === 9. === === 9. ===
 Click the **DONE** button at the bottom of the page to back out to the configuration screen. Click the **DONE** button at the bottom of the page to back out to the configuration screen.
 +----
 +=== 10. ===
 +In the device configuration screen, click the back arrow at the top left of the page to return to the device selection screen.
 </WRAP> </WRAP>
 <WRAP column half> <WRAP column half>
-{{ :reference:instrumentation:openlogger:initial_instrument_panel.png?500 |Initial Instrument Panel}}+{{ reference:test-and-measurement:openlogger:calibration_complete.png?500 |Calibration complete}}
 </WRAP> </WRAP>
 </WRAP> </WRAP>
  
-<WRAP group> +---- 
-<WRAP column half> +===== More Information ===== 
-=== 10. === + 
-In the device configuration screenclick the back arrow at the top left of the page to return to the device selection screen. +Check out the OpenLogger's [[test-and-measurement:openlogger:start|Resource Center]] for more guidestutorials, and projects.
-</WRAP> +
-</WRAP>+
  
 {{tag>openlogger}} {{tag>openlogger}}
 {{include_n>4}} {{include_n>4}}