Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
Last revisionBoth sides next revision
test-and-measurement:analog-discovery-pro-5250:start [2021/11/30 22:03] – Fix page title to follow naming conventions Arthur Browntest-and-measurement:analog-discovery-pro-5250:start [2024/02/28 20:11] – [Tutorials] Arthur Brown
Line 6: Line 6:
 | Getting Started = getting-started-guide | Getting Started = getting-started-guide
 | Manual = [[reference-manual]] | Manual = [[reference-manual]]
-| Support = https://forum.digilentinc.com/forum/8-scopes-instruments/ +| Support = https://forum.digilent.com/forum/8-scopes-instruments/ 
-| Title = Analog Discovery Pro ADP5250+| Title = Analog Discovery Pro (ADP5250)
 | Subtitle = Portable High Resolution Mixed Signal Oscilloscopes | Subtitle = Portable High Resolution Mixed Signal Oscilloscopes
  
Line 13: Line 13:
 | WaveForms = [[software:waveforms:waveforms-3:start|Resource Center]] | WaveForms = [[software:waveforms:waveforms-3:start|Resource Center]]
 | WaveForms SDK = [[software:waveforms:waveforms-sdk:start|Resource Center]] | WaveForms SDK = [[software:waveforms:waveforms-sdk:start|Resource Center]]
 +| Bullet = The ADP5250 is Windows® only
  
- +| Header = Mixed Signal Oscilloscope - Analog Inputs
-| Header = Oscilloscope+
 | Channels = 2 single ended, non-isolated | Channels = 2 single ended, non-isolated
-| Resolution = 8-bits +| Resolution = 8 bits 
-| Sample Rate = 1 GS/s single channel, 500 MS/s/channel in dual channel mode +| Sample Rate = 1 GS/s single channel, 500 MS/s per channel in dual channel mode 
-Maximum input range = 40 V peak to peak+Input Range = 40 V peak to peak, maximum
 | Bandwidth (-3dB) = 100 MHz | Bandwidth (-3dB) = 100 MHz
 | Input Impedance = 1 MΩ ││ 20 pF | Input Impedance = 1 MΩ ││ 20 pF
 | Accuracy = ±2% of input / ±1% full scale | Accuracy = ±2% of input / ±1% full scale
-Max Buffer Size = 1 MS/channel+| Buffer Size = 1 MS per channel, maximum
  
-| Header = Triggering +| Header = Mixed Signal Oscilloscope - Digital Inputs 
-Trigger Modes Normal, Auto, Force, Single +Channels 32 
-Trigger Sources Oscilloscope analog channels, Oscilloscope digital channels, Function generator start, Digital I/O lines, External trigger (TRIG), Power line frequency +Sample Rate 1 GS/s 
-Trigger Types  Edge with hysteresis (analog); Edge, pattern, glitch, level (digital) +Record Length 1 MS typical 
-Trigger Resolution 667 ps (analog) 1 ns (digital)+Input Voltage 0 V to 5 V 
 +| Input Threshold = 0 V to 2 V
  
 | Header = Arbitrary Waveform Generator (Wavegen) | Header = Arbitrary Waveform Generator (Wavegen)
 | Channels = 1 | Channels = 1
-| Resolution = 14-bit+| Resolution = 14 bits
 | Sample Rate = 125 MS/s  | Sample Rate = 125 MS/s 
 | Output Impedance = 50 Ω | Output Impedance = 50 Ω
 | Switchable Filter = 36 MHz lowpass, 7-pole, elliptical | Switchable Filter = 36 MHz lowpass, 7-pole, elliptical
-| Ramp / Triangle maximum frequency = 1 MHz +| Output Range =  ±12 V, maximum 
-| Output Range =  ±6V (50 Ω) +| DC Offset = ±12 V, maximum
-| Output Range = ±12V (Hi-Z) +
-| DC Offset = ±6V (50 Ω) +
-| DC Offset = ±12V (Hi-Z) +
-| Frequency (accuracy) = ≤ 100 ppm +
-| Frequency (resolution) = 1 µHz +
-| Arbitrary Wave Form (points) = 1 MS +
-| Arbitrary Wave Form (resolution) = 125 MS / s+
  
 +| Header = Data Logger
 +| Channels = 2 (Shared with Oscilloscope)
 +| Supported Measurements = DC, True RMS, AC RMS, Custom
  
 | Header = Programmable Power Supply | Header = Programmable Power Supply
-| Outputs = 0 to +6V / 0 to 1A \\ 0 to +25V / 0 to 500 mA (isolated) \\ 0 to -25V / 0 to 500 mA (isolated)+| Outputs = 0 to +6 V / 0 to 1 A \\ 0 to +25 V / 0 to 500 mA (isolated) \\ 0 to -25 V / 0 to 500 mA (isolated)
  
 | Header = Digital Multimeter | Header = Digital Multimeter
 | Measurements = DC Voltage, AC Voltage, AC Current, Resistance, Diode, Continuity | Measurements = DC Voltage, AC Voltage, AC Current, Resistance, Diode, Continuity
-| Digits = 5 1/2 +| Digits =  
-DC 300 V +Sample Rate 5 S/s
-| AC = 265 V+
  
 | Header = Digital I/O | Header = Digital I/O
 | Channels = 8 | Channels = 8
-| Direction Control = input or output +| Logic Level 5 V compatible TTL input / 3.3 V LVTTL output
-| Logic level 5V compatible TTL input / 3.3V LVTTL output +
-| Drive strength = 4 mA +
-| Input Voltage = 0 to 5V +
- +
-| Header = Mixed Signal Oscilloscope +
-| Digital Inputs = 34 +
-| Digital Sample Rate = 1 GS/s +
-| Record Length = 1 MS typical +
-| Analog = 2 (on BNC Connectors) +
-| Analog Sample Rate = 1 GS/s +
-| Analog Record Length = 1 MS per channel+
  
 | Header = Logic Analyzer | Header = Logic Analyzer
-Channels 32 +Bullet Shares digital inputs with Mixed Signal Oscilloscope
-| Maximum input Frequency = 100 MHz +
-| Input Level = 0 to 5 V +
-| Sample Rate = 1 GS/s (down to ~15 kS/s)+
  
 | Header = Spectrum Analyzer | Header = Spectrum Analyzer
 +| Inputs = Shared with Oscilloscope
 | Frequency Range = DC to max bandwidth of scope | Frequency Range = DC to max bandwidth of scope
 | Display Modes = magnitude, average, peak hold, min hold, count | Display Modes = magnitude, average, peak hold, min hold, count
Line 85: Line 68:
 | Inputs / Outputs = Shared with Oscilloscope and Waveform Generator  | Inputs / Outputs = Shared with Oscilloscope and Waveform Generator 
 | Frequency Sweep Range = 1 mHz to 10 MHz | Frequency Sweep Range = 1 mHz to 10 MHz
-| Samples = up to 10k samples per decade 
  
 | Header = Product Compliance | Header = Product Compliance
Line 111: Line 93:
   * [[test-and-measurement:guides:waveforms-oscilloscope]]   * [[test-and-measurement:guides:waveforms-oscilloscope]]
   * [[test-and-measurement:guides:waveforms-waveform-generator]]   * [[test-and-measurement:guides:waveforms-waveform-generator]]
-  * [[test-and-measurement:guides:waveforms-supplies]]+  * [[test-and-measurement:guides:waveforms-readback-supplies]]
   * [[test-and-measurement:guides:waveforms-dmm]]   * [[test-and-measurement:guides:waveforms-dmm]]
 +  * [[test-and-measurement:guides:waveforms-data-logger]]
   * [[test-and-measurement:guides:waveforms-logic-analyzer]]   * [[test-and-measurement:guides:waveforms-logic-analyzer]]
   * [[test-and-measurement:guides:waveforms-static-io]]   * [[test-and-measurement:guides:waveforms-static-io]]
Line 126: Line 109:
   * [[test-and-measurement:guides:waveforms-cross-triggers]]   * [[test-and-measurement:guides:waveforms-cross-triggers]]
   * [[test-and-measurement:guides:waveforms-external-triggers]]   * [[test-and-measurement:guides:waveforms-external-triggers]]
-  * [[test-and-measurement:guides:waveforms-using-waveforms-sdk]]+  * [[test-and-measurement:guides:waveforms-sdk-getting-started]] 
 +  * [[test-and-measurement:guides:getting-started-with-labview]]
  
 ---- ----
 ===== Featured Projects ===== ===== Featured Projects =====
 +  * [[transistor-tester]]
   * [[power-measurement-demo]]   * [[power-measurement-demo]]
-  * [[test-and-measurement:guides:manchester-encoding]]+  * [[rf-demo]] 
 +  * [[fm-radio]]
  
 ---- ----
Line 147: Line 133:
  
 ===== Additional Resources ===== ===== Additional Resources =====
-  * {{reference:test-and-measurement:analog-discovery-pro-5250:adp5250_statement_of_volatility.pdf|Statement of Volatility}}+  * [[certifications]] 
 +  * {{https://files.digilent.com/resources/test-and-measurement/analog-discovery-pro-5250/adp5250-statement-of-volatility.pdf|Statement of Volatility}} 
 + 
 +/*https://www.ni.com/en-us/support/documentation/dimensional-drawings/model.vb-8012.html 2D and 3D models of virtual bench 
 +https://www.ni.com/pdf/manuals/371528e.pdf calibration procedure 
 +https://www.ni.com/pdf/manuals/375043d.pdf only documentation mentioned the scope compensation tabs on the front panel*
  
 ---- ----