Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
learn:instrumentation:tutorials:analog-discovery-studio-supplies:start [2019/06/07 17:20] – [Next Steps] kaitlyn Franzlearn:instrumentation:tutorials:analog-discovery-studio-supplies:start [2021/06/02 23:47] (current) Arthur Brown
Line 1: Line 1:
-====== Using the Power Supplies ======+====== Using the Power Supplies (REDIRECT) ====== 
 +~~REDIRECT>test-and-measurement/guides/waveforms-supplies~~ 
 +~~NOSEMANTIC~~ 
 +{{tag>redirect}}
  
-{{:reference:instrumentation:analog-discovery-studio:hardware-reference-manual:supplies.png?nolink&800}} 
  
-This guide walks through the process of setting up WaveForms' Power Supplies instrument and using it to configure a Test and Measurement Device's Power Supplies. The user interface of the instrument is briefly described. 
- 
-**Note:** //This guide only pertains to the Analog Discovery 2 and Analog Discovery Studio. Other Digilent Test & Measurement devices have a different UI for their //Supplies// instrument.// 
- 
-==== 1. Opening the Supplies Instrument ==== 
-<WRAP group> 
-<WRAP column half> 
-== 1.1 == 
-Plug in your Test & Measurement Device, then start WaveForms and make sure your device is connected. 
- 
-If no device is connected to the host computer when WaveForms launches, the **Device Manager** will be launched. Make sure that the device is plugged in and turned on, at which point it will appear in the Device Manager's device list (1). Click on the device in the list to select it, then click the **Select** button (2) to close the Device Manager. 
- 
-**Note:** //"DEMO" devices are also listed, which allow the user to use WaveForms and create projects without a physical device.// 
- 
-**Note:** //The Device Manager can be opened by clicking on the "Connected Device" button in the bottom right corner of the screen (3), or by selecting "Device Manager" from the "Settings" menu at the top of the screen.// 
-</WRAP> 
-<WRAP column half> 
-{{ :learn:instrumentation:tutorials:analog-discovery-studio-oscilloscope:waveforms-device-manager.png?600 |}} 
-</WRAP> 
-</WRAP> 
----- 
-<WRAP group><WRAP column half> 
-== 1.2 == 
-Once the Welcome page loads, in the instrument panel at the left side of the window, click on the **Supplies** button to open the //Power Supplies// instrument. 
-</WRAP><WRAP column half> 
-{{ :learn:instrumentation:tutorials:waveforms-instrument-panel:waveforms-instrument-panel-supplies.png?nolink&600 |}} 
-</WRAP></WRAP> 
----- 
-<WRAP group><WRAP column half> 
-== 1.3 == 
-Once the Supplies instrument opens, the window contains the controls for the two variable power supply rails, described in the next section. 
-</WRAP><WRAP column half> 
-{{:reference:instrumentation:analog-discovery-studio:hardware-reference-manual:supplies.png?nolink&600}} 
-</WRAP></WRAP> 
----- 
-==== 2. Using the Supplies ==== 
-//This section walks through setting up the power supplies and voltmeter to measure the DC output of the power supplies// 
-<WRAP group> 
-<WRAP column half> 
-== 2.1 Hardware Setup == 
-In order to measure the output of the variable power supply pins, these pins must be connected to something that can measure voltages. While a standard digital multimeter or voltmeter could be used, this guide will show how to use WaveForms' //Voltmeter// instrument to measure the supply voltages. 
- 
-Connect the <test & measurement device>'s positive variable supply output pin (red wire, labeled "V+") to the device's analog input channel 1 pin (orange wire, "1+"). 
- 
-Connect the <test & measurement device>'s negative variable supply output pin (white wire, "V-") to the device's analog input channel 2 pin (blue wire, "2+"). 
- 
-If the <test & measurement device> has differential analog input channels, make sure to connect the analog input channel negative pins, labeled "1-" (orange wire with white stripes) and "2-" (blue wire with white stripes) to the device's ground (black wire, marked with a down arrow). 
-</WRAP> 
-<WRAP column half> 
-{{ :learn:instrumentation:tutorials:analog-discovery-studio-supplies:power-supply-hw-setup.png?nolink&600 |}} 
-</WRAP> 
-</WRAP> 
----- 
-<WRAP group> 
-<WRAP column half> 
-== 2.2 Software Setup == 
-With the loopback circuit set up, WaveForms' //Voltmeter// instrument must be set up to report measured DC voltages. 
- 
-From the //Supplies// tab, opened in step 1.2, return to WaveForms' Welcome page by clicking on its tab at the top of the screen. In the Welcome tab, open the //Voltmeter// instrument, then click the "Run" button ({{:learn:instrumentation:tutorials:waveforms-buttons:waveforms-run.png?nolink}}) in the control bar near the top of the window to begin capturing data. The DC voltage measured on each analog input channel is reported in the "DC" row of the table just below the Run button. 
-</WRAP> 
-<WRAP column half> 
-{{ :learn:instrumentation:tutorials:waveforms-instrument-panel:waveforms-instrument-panel-voltmeter.png?nolink&600 |}} 
-</WRAP> 
-</WRAP> 
-<WRAP group> 
-<WRAP column half> 
-In order to show both the //Voltmeter// and the //Supplies// instruments on the screen at once, click on the "Docking Windows" button in the top right corner of the screen.  
- 
-**Note:** To return to the default tabbed view later, click on the "Tabbed Windows" button adjacent to the Docking Windows button. 
-</WRAP> 
-<WRAP column half> 
-{{ :learn:instrumentation:tutorials:analog-discovery-studio-supplies:waveforms-supplies-docking-windows.png?nolink&600 |}} 
-</WRAP> 
-</WRAP> 
----- 
-<WRAP group> 
-<WRAP column half> 
-== 2.3 Enable the Supplies == 
-When the //Supplies// instrument is first opened, the power supplies are disabled. 
- 
-The "Master Enable" button can be used to switch both of the variable supplies off or on at once. The "Positive Supply" and "Negative Supply" buttons can be used to enable or disable each of the two variable supplies individually. While the Master Enable is off, each power supply can be set to a Ready or Off state, if the supply is ready, it will be turned on when the Master Enable is set to on. 
- 
-Make sure that both power supplies are ready, then click on the Master Enable button to turn both of them on. 
-</WRAP> 
-<WRAP column half> 
-{{ :learn:instrumentation:tutorials:analog-discovery-studio-supplies:waveforms-supplies-enables.png?nolink&600 |}} 
-</WRAP> 
-</WRAP> 
----- 
- 
-==== 3. Power Supplies User Interface Walkaround ==== 
-The remainder of this guide describes the functionality of the rest of the //Power Supplies// user interface. While following along, experiment with power supply controls described, and look back at the Voltmeter to see how they the voltage outputted by the variable supplies is affected. 
----- 
-<WRAP group> 
-<WRAP column half> 
-== 3.1 Individual Supply Controls == 
-Each "Voltage" field (labeled **1.** in the image to the right) can be used to set the voltage output by that supply. This field can be set by either typing a voltage value, including units, into the text field, or by using the dropdown to select a value. When a value is entered that is outside of the possible range for the <test & measurement device>, the value is clamped to the nearest voltage that can be output. 
- 
-The output voltage level can also be changed by adjusting the slider (**2.**) to the right of the voltage field. 
- 
-The gear button ({{:learn:instrumentation:tutorials:waveforms-buttons:waveforms-gear.png?nolink}}) to the left of the slider allows the user to narrow the range of voltages that can be used for both the slider and Voltage field for that channel. 
- 
-As previously mentioned in step 2.3 of this guide, each power supply has its own enable/disable button (**3.**). 
-</WRAP> 
-<WRAP column half> 
-{{ :learn:instrumentation:tutorials:analog-discovery-studio-supplies:waveforms-supplies-individual.png?nolink&600 |}} 
-</WRAP> 
-</WRAP> 
----- 
-<WRAP group> 
-<WRAP column half> 
-== 3.2 Controlling both Supplies == 
-As previously mentioned, each supply can be enabled or disabled at once using the Master Enable button. 
- 
-The "Tracking" checkbox, between the two channels, when checked, mirrors any changes made to the voltage output by one channel on the other channel. For example, if the positive supply is set to output 2V, the negative supply will automatically be changed to output -2V. 
-</WRAP> 
-<WRAP column half> 
-{{ :learn:instrumentation:tutorials:analog-discovery-studio-supplies:waveforms-supplies-tracking.png?nolink&600 |}} 
-</WRAP> 
-</WRAP> 
----- 
-<WRAP group> 
-<WRAP column half> 
-== 3.3 Menu Bar == 
-The "File" menu, in the menu bar at the top of the supplies instrument, allows the user to save and load //Supplies// instrument configurations. 
- 
-The "Control" menu exposes the same functionality as the Master Enable Button, and lists hotkeys that can be used to quickly stop and run the power supplies. 
- 
-The Window menu provides a fast way to switch to other tabs open in WaveForms. 
-</WRAP> 
-<WRAP column half> 
-{{ :learn:instrumentation:tutorials:analog-discovery-studio-supplies:waveforms-supplies-menu-bar.png?nolink&600 |}} 
-</WRAP> 
-</WRAP> 
----- 
-==== Next Steps ==== 
- 
-/* 
-If voltage values seen in the //Voltmeter// are significantly different from the expected voltage output of the //Supplies//, please calibrate the device by following the **Calibration Guide**. FIXME link 
-*/ 
- 
-For more guides on how to use the Digilent Test & Measurement Device, return to the device's Resource Center, linked from [[reference:instrumentation:start|Instrumentation]] page of this wiki. 
- 
-For more information on WaveForms visit the [[reference:software:waveforms:waveforms-3:reference-manual|WaveForms Reference Manual]].  
- 
-For technical support, please visit the [[https://forum.digilentinc.com/forum/8-scopes-instruments/|Scopes and Instruments]] section of the Digilent Forums. 
- 
-{{tag>analog-discovery-studio tutorial}}