Pmod TC1

Buy Reference Manual Technical Support
Pmod TC1
K-Type Thermocouple Module with Wire
Features
  • K-type thermocouple-to-digital converter
  • Wide temperature range of -73°C to 482°C with provided wire
  • ±2°C accuracy from -200°C to 700°C
  • 14-bit with 0.25°C resolution
  • Cold-junction temperature compensation
  • 6-pin Pmod port with SPI interface
Electrical
Bus
SPI
Specification Version
1.2.0
Logic Level
3.3V
Physical
Width
1.0 in (2.54 cm)
Length
0.80 in (2.03 cm)
Documentation
Primary IC
Thermocouple wire
Reference Manual
Schematic
3D Model
J1 Pinout
Pin 1
CS
Pin 2
NC
Pin 3
MISO
Pin 4
SCLK
Pin 5
GND
Pin 6
VCC

The Digilent Pmod TC1 (Revision A) is a cold-junction thermocouple-to-digital converter module designed for a classic K-Type thermocouple wire. With Maxim Integrated's MAX31855, this module reports the measured temperature in 14-bits with 0.25°C resolution.



Example Projects

Microprocessor
Programmable Logic

Additional Resources

  • Specification Version 1.2.0: PDF