====== High Current Adapter for NI myRIO ====== {{:ni:highcurrentadapter-600.png?500|}} ===== Overview ===== The High Current Adapter for NI myRIO allows you drive high power low speed currents using relays and open drain N-FET otputs trough MXP connector on your myRIO. The switched signals are connected with screw terminals. For open drains a power supply is needed. Key Features: * Supports 3V...16V power voltage(external power supply required) * 4 Open drain outputs *Continuous current:3.0A(25°C)/2.2A(85°C) * Peak output current:4.1A(t<5s) * 4 Standard 3 terminal relay outputs * Common, Normally Closed, Normally Open * Relay output max switching voltage:30V * Rated current:1A * 34-pin female breakout allowing direct access to signal pins * Uses the myRIO Expansion Port(MXP) connector **Connector Pin-outs** __Relay connectors__ : ^ Signal ^ Description ^ | NOx | Normal Open | | NCx | Normal Close | | COMx | Common terminal | __Open Drains__ : ^ Signal ^ Description ^ | ODx- | Open Drain negative terminal | | ODx+ , PWR+ | Supply voltage (internally connected) | | PWR- | Ground | **Using the Adapter with myRIO** ***Relays*** are single side stable Normal Connected between NC and COM terminals. A logic "high" will energize the coil and the COM will be shorted to NO. ***Open Drains*** connectors are meant to be used with two polarized pins/channel. The OD+ is connected to PWR positive power terminal. The OD- is equipped with transient suppression diodes to the PWR. Connect open drains power supply(+PWR-) respecting the polarity. PWR should not exceed 16VDC. Note:If you need different supplies for different channels, assure suppression diodes to your supply voltages, especially when use inductive loads.